




FLUKE 705 Loop Calibrator; 28V Voltage; 24mA Current
The Fluke 705 loop calibrator is a cost-effective tool for calibrating, repairing and maintaining 4–20 mA loops, with simultaneous mA and % readout, measuring up to 28 V DC and 24 mA.
Product Overview
Instrument technicians spend much of their time checking 4–20 mA loops between transmitters, controllers and valves. The Fluke 705 is a cost-effective, integrated solution for calibrating, repairing and maintaining milliamp loops.
It shows mA and percentage of span at the same time, which makes readings quick to interpret, and it has a large display and a simple pushbutton interface. Its ranges cover up to 28 V DC and 24 mA.
Supply in Dubai and the GCC
We supply the Fluke 705 from Dubai to instrumentation and maintenance teams in oil and gas, power, water and manufacturing across the UAE and the GCC.
Technical Specifications
Key Features
- Calibrates, repairs and maintains mA loops
- Simultaneous mA and % readout
- Large display
- Simple pushbutton interface
- Up to 28 V DC and 24 mA
Typical Applications
- 4–20 mA transmitter checks
- Control loop troubleshooting
- Valve and positioner testing
- Instrument commissioning
Frequently Asked Questions
What is the Fluke 705 used for?
Calibrating, repairing and maintaining 4–20 mA loops in process instrumentation.
Does the Fluke 705 show percentage of span?
Yes. It shows the mA value and the percentage of span at the same time.
Do you supply FLUKE 705 Loop Calibrator; 28V Voltage; 24mA Current in Dubai and the rest of the UAE?
Yes. HNA Enterprises supplies FLUKE 705 Loop Calibrator; 28V Voltage; 24mA Current from FLUKE from Dubai to customers across the UAE, including Abu Dhabi, Sharjah, Ajman and Ras Al Khaimah, and to Saudi Arabia, Qatar, Kuwait, Oman and Bahrain.
How do I get a price for FLUKE 705 Loop Calibrator; 28V Voltage; 24mA Current?
Prices depend on the quantity and pack size you need. Send a quote request on WhatsApp or through our contact page with the product name and quantity, and our sales team will reply with a price and lead time.
Can I get the technical or safety data sheet for FLUKE 705 Loop Calibrator; 28V Voltage; 24mA Current?
Yes. Ask for the manufacturer's technical data sheet (TDS) or safety data sheet (SDS) when you request your quote and we will send it with our reply.
Related Products

FLUKE 707 Loop Calibrator with Quick Click Knob; 28V Voltage; 24mA Current
The Fluke 707 is a mA loop calibrator with a Quick Click knob that sources, simulates and measures mA, with HART-compatible loop resistance, 25% steps, span check and ramp outputs.

FLUKE 709 Precision Loop Calibrator 10 to 95% non-condensing
The Fluke 709 is a precision mA loop calibrator with 0.01% of reading accuracy, 1 µA and 1 mV resolution, a Quick-Set knob and valve test functions.

FLUKE 709H Precision HART Loop Calibrator
The Fluke 709H is a precision mA loop calibrator with HART communication, 1 µA resolution on mA ranges and 1 mV on voltage ranges, and data logging for documentation.

FLUKE 710 MA LOOP VALVE TESTER
The Fluke 710 is a mA loop calibrator with built-in valve test procedures for HART smart control valves, giving a Good, Marginal or Bad assessment, with 0.01% mA accuracy.

FLUKE 715 Volt/mA Loop Calibrator
The Fluke 715 is a volt/mA loop calibrator that measures loop current with 0.01% accuracy and 1 µA resolution, sources 200 mV or 20 V, simulates 4–20 mA and provides a 24 V loop supply.

FLUKE 77-4-EUR Digital Multimeter 1000V – 6000Count
The Fluke 77 IV is a 1000 V, 6000-count digital multimeter for field service or bench repair, with 0.3% accuracy and 10 A current (20 A for 30 seconds).

FLUKE 805 FC Vibration Meter with Fluke Connect
The Fluke 805 FC is a vibration meter for checking bearings and overall vibration, with a sensor design that reduces variation from angle and pressure, a four-level severity scale and Fluke Connect.

FLUKE 810 Vibration Tester
The Fluke 810 Vibration Tester identifies and locates the most common mechanical faults (bearings, misalignment, unbalance and looseness) on board, with a four-level fault severity scale.